Industrial Hygiene Dashboard
This panel gathers the company’s measurements of physical agents: noise, lighting, vibration and thermal stress. From here you go into each agent; the same guide serves the screen of each agent and the calculators.
1. What is on the panel
At the top are the title “Industrial Hygiene Dashboard”, the company name with the time of the last update and the “Refresh” button.
Below are two cards with a number: “Do now” (“Overdue or legal duty”) and “Plan” (“Due in 30 days”). If there is nothing they say “Nothing pending”. Click one and the “What to do” list keeps only those actions; that list gathers what is pending in hygiene ordered by date.
2. The table by agent
“By agent” has one row per agent: “Noise” (RD 286/2006), “Lighting” (RD 486/1997, annex IV), “Vibration” (RD 1311/2005) and “Thermal stress” (UNE-EN ISO 7243, WBGT). The columns are “Agent”, “Worst result against the limit” and “Next measurement”. Each row says how many measurements there are and the date of the last one.
The tag on the right is the worst result against the limit: green if below the action values, amber if it exceeds them or sits at the required lighting level, and red if it exceeds the limit value or falls short of the required lighting level. Click a row to open that agent’s measurements; its menu has “View measurements” and “New measurement”.
While there are no measurements, the panel says “No hygiene measurements yet”, with the “Schedule the first measurement” button and a “What to measure” list giving the reason to measure each agent.
3. Recording a measurement
1. Choose the agent (a row of the panel or the Industrial Hygiene menu) and click “New measurement”.
2. In the form write the title, the measurement type, the workplace, the department, the location, the scheduled date, the technician and the equipment data with its calibration. Click “Create measurement”: it is left as “Draft”.
3. In the measurement, click “Start Measurement” (“Start Assessment” for thermal stress) and “Add Point” for each measured point, with its values.
4. Click “Complete and Calculate” (“Complete” for lighting): the application calculates the result with the agent’s standard. If it exceeds the action values, “Action Required” appears and the measurement counts in the panel’s actions until it is resolved.
5. “Submit for Review”, “Approve” and “Download Report” close the process.
4. Each agent’s list
Each agent has its own list: “Noise Measurements”, “Lighting Measurements”, “Vibration Measurements” and “Thermal Stress Assessments”. While it is empty it says, for example, “No noise measurements yet”, with the “Record the first measurement” button.
With measurements there are a search box (“Search by title or code”), one button per status (“Draft”, “In Progress”, “Completed”, “Under Review”, “Approved” and “Rejected”) and “More filters”, with a second filter specific to the agent (exposure level, compliance, vibration type or heat stress level). The columns are “Measurement”, “Status” and “Date”; a measurement still to be made whose scheduled date has passed is shown in red. The header menu has “Export to Excel”.
5. The calculators
In the menu, Industrial Hygiene › Calculators does one-off calculations without saving any measurement. It has one tab per calculation: “Noise”, “Lighting”, “Vibration”, “Heat stress (WBGT)”, “Room conditions”, “Lifting” and “Hearing protectors”.
Fill in the data and click “Calculate”: below, under “Result”, appear the value, the threshold exceeded stated in words and the standard it is based on. For example, in vibration you add one row per tool with its minutes per shift and its acceleration and get the daily exposure.
6. Permissions
Recording or editing measurements requires write permission. By default the prevention module is open to editors and administrators; a read-only user sees the notice “This module is switched off”.