Non-conformities

“Non-Conformities” records each non-compliance found (in an audit, an inspection, an incident or a complaint), its root cause and the actions to correct it, until they are verified as effective and it is closed. The screen cites clause 10.2 of ISO 45001. Each non-conformity belongs to a standard (ISO 45001, ISO 9001, IFS, GlobalG.A.P.…), chosen in the form; your company’s standards are recorded in “Standards and certificates”.

1. The list

Once there are records, four cards count and filter: “Overdue”, “Due in 30 days”, “Awaiting effectiveness check” and “Open”. Click one to filter and click it again to remove the filter.

Below are the search box (by number, title or area), the statuses with their counts (“Open”, “In progress”, “Pending verification”, “Verified”, “Closed”, “Rejected”) and “More filters”, which adds type and source. Each row shows the title (it opens the record), number, type, area, owner, status and due date, in red if it has passed.

2. Recording a non-conformity

Click “New Non-Conformity”. The “Title” and the “Detected date” are required. Choose the “Type” and the “Source” (internal or external audit, inspection, incident, complaint, self-assessment, equipment), set the “Due date” and the “Area / process affected”.

In “Root cause & CAPA” write the immediate, corrective and preventive actions. Save with “Create”. The root cause is written afterwards in the record: the “Record root cause” button opens its analysis.

3. Treating, verifying and closing

The main button on the record is the next step: “Start treatment”, “Record root cause” (In progress with no root cause), “Request verification”, “Verify effectiveness” and “Close”. Only a verified non-conformity can be closed.

In the “More” menu, “Not effective” (in Pending verification) sends it back to In progress and “Reject” (in Open or In progress) discards it; both ask for the reason.

The “Cause and actions” tab lists its actions and “New action” creates another with the non-conformity as its source; evidence is uploaded under “Documents” with “Upload document”.

In the “Cause and actions” tab, “Root cause analysis” guides the 5 whys and the fishbone (method, machine, material, people, measurement and environment). “Save analysis” copies the conclusion as the root cause and “Ask Nora to review it” shows what is missing and what Nora thinks. “More” → “Print with the root cause analysis” opens a page ready to print or save as PDF.

4. Who sees what

Creating, editing, moving forward and deleting need edit permission; without it you can only view. If your role does not have the Quality and Improvement module, you see “This module is switched off”. Overdue non-conformities appear under “What to do” on the Improvement dashboard.