The "Drills" tab of an emergency plan is used to schedule a drill, convene the emergency team and the workers, record how it went and turn what failed into preventive measures. It opens from "Emergencies", in the Environment menu, when you open an emergency plan.
1. Scheduling a drill
"Plan a drill" (for those who can edit, and only with the plan in force) opens "Plan a drill": "Scenario" (Fire, Evacuation, Chemical spill, Medical emergency, Bomb threat or Other), "Date and time", "Workplace" (by default "All workplaces") and the checkbox "Unannounced drill". It is saved with "Plan drill". A plan that is not in force replies "The plan must be in force before a drill is planned.": approve it first.
2. Convening the team and the workers
Each scheduled drill shows "Announced" or "Unannounced" and two convocation blocks: "Emergency team and observers" and, if it is announced, "Workers". In each one, "Convene" opens the convocation of type Drill with the drill's date and work centre (sending, confirmations and attendance as explained in the "Convocations" guide).
Workers are not convened to an unannounced drill: their block does not appear and the server rejects it; only the emergency team and the observers are convened. "Cancel drill" also cancels its convocations.
3. Recording the execution and the findings
"Record execution" opens "Record the drill": "Date carried out" (it cannot be in the future), "Evacuation (minutes)" and "Evacuation (seconds)", "Participants" (if you leave it empty, the people marked as attendees in the convocations are counted), "Observers", "Notes" and "Findings". Each finding has "What failed or can improve", "Severity" (Low, Medium or High), "Responsible" and "Due date".
"Save drill" sets it to "Done", updates the date of the plan's last drill and calculates the next one with the plan's frequency, and archives in Documents the PDF report ("Report filed in Documents"). The "Record drill" button in the plan header saves only the date and the result.
4. From finding to preventive measure, and the report
In a completed drill, each finding has "Create preventive measure", which is enabled when it has a responsible person ("Choose a responsible user when recording the drill to create the measure."). The measure is of organisational type, with the priority that corresponds to the severity (high, medium or low), the responsible person and the due date of the finding; afterwards the finding shows "Open measure". The drill findings appear in "Follow-up" as "Drill finding". "Download report" downloads the drill's PDF report.